Requirements
Form, pour, and finish house slab on grade, 3500 psi, 10 mill Stego wrap vapor barrier
Perimeter footing 18" x12", reinforced with two #5 rebar continuous
6" French Drain on back sde of house per sketch with three outlets
8" concrete back wall 10' tall reinforced two rows of #5 rebar per sketch
3' of drainage gravel behind wall and around under ground room
12" concrete lid on 16x16 under ground room, with 3 rows of rebar mats on 12" centers each way
Water proofing walls and lid
ICF Block walls on front and sides
Interior wood framing
Wood trusses and decking
Ice and water, and 30# felt
50 year architectural shingles" GAF Grand Manor" OPTION (50,000 LESS)
24 ga lockseam Panel
3' of drainage gravel behind wall and around under ground room12" concrete lid on 16x16 under ground room, with 3 rows of rebar mats on 12" centers each way
Water proofing walls and lidICF Block walls on front, back and sides
Interior wood framing
Wood trusses and decking
Ice and water, and 30#felt50 year architectural shingles" GAF Grand Manor"
Authorized by:
Bryan Hebert